Warm Edge Spacer Windows: Materials, Psi Values and Size Effects
A thermally improved spacer meets the cross-sectional criterion Σ(d × λ) ≤ 0.007 W/K, where d is material thickness in metres and λ is conductivity in W/(m·K). For BF’s reference thermally broken metal frame with 4/16/4 double glazing and Ug 1.1 W/(m²·K), the cited thin-stainless-steel spacer gives ψg 0.068 and the cited SAN-GF/metallised-polyester-foil spacer gives 0.036 W/(m·K).
The details behind the answer
Junction values apply to those reference assemblies.
What does the warm-edge criterion actually measure?
The thermally improved spacer criterion is Σ(d × λ) ≤ 0.007 W/K, using material thickness d in metres and conductivity λ in W/(m·K). It evaluates the spacer cross-section. Junction ψg describes the extra edge heat flow in the assembled frame-and-glass detail. Whole-window Uw combines the glass, frame and edge contributions.
A ψg of 0.068 W/(m·K) means an additional 0.068 watts per metre of glass-frame junction for each kelvin of indoor-outdoor temperature difference. Multiplying ψg by the glass-edge length gives the edge term in the window’s heat-loss coefficient. The Ug and Uf area terms account for the glass centre and frame separately.
Read the spacer's structural cross-section together with its sealing surfaces. The glass-facing sides receive the primary seal, while the back and corners participate in the complete edge construction. This helps distinguish a change of spacer material from a change of the whole edge system.
Which parts of a composite spacer belong in the manufacturing choice?
One Chinese-language manufacturer catalogue describes a polypropylene and ultra-thin stainless-steel composite, with a small-cavity option for widths within 10 mm. Its body and metallic barrier have a specific processing method.
Match the spacer width to the intended cavity, then match its body height and barrier surface to the secondary seal and corner construction. A narrow cavity, a curved unit and a large rectangular pane can lead to different fabrication choices even where the thermal target is similar.
One Chinese warm-edge IGU fabricator lists 5–19 mm single-pane processing, with silicone secondary seals for its curtain-wall option and polysulfide for its window option. Use the selected glass and compatible seal assembly on the fabrication drawing.
Spacer body, barrier, seals and glass bite work together at the glazing edge.
How do two spacer constructions compare at the same junction?
For BF’s reference thermally broken metal frame with 4/16/4 double glazing and Ug 1.1 W/(m²·K), the cited thin-stainless-steel spacer gives ψg 0.068 and the cited SAN-GF/metallised-polyester-foil spacer gives 0.036 W/(m·K).
| Reference construction | Body height | ψg with 4 mm panes, W/(m·K) | ψg after correction to 6 mm panes, W/(m·K) |
|---|---|---|---|
| Cited thin-stainless-steel spacer | 6.5 mm / 0.26 in | 0.068 | 0.074 |
| Cited SAN-GF/metallised-polyester-foil spacer | 6.5 mm / 0.26 in | 0.036 | 0.042 |
How do thicker panes change the representative psi input?
Changing both panes from 4 to 6 mm adds 0.006 W/(m·K) to each reference ψg value, producing corrected values of 0.074 and 0.042 W/(m·K). The correction is 0.001 per extra millimetre of outer glass plus 0.002 per extra millimetre of inner glass.
Apply the appropriate correction before putting the spacer into a window calculation. Carry the actual pane thicknesses from the safety-glass schedule into the thermal schedule, especially when larger panes require thicker glass.
The BF association download index provides current calculation material. Check the applicable frame category, glazing construction and validity when the design is finalized. BF states a calculation-method accuracy of ±0.003 W/(m·K), with differences below 0.005 W/(m·K) treated as insignificant.
At equal 2.88 m² total window area, the stated four-small-window calculation reduces Uw by 0.132 W/(m²·K) and the single-large-window calculation by 0.073, using the specified frame, glass and corrected junction inputs.
Why do small windows gain more from the same spacer change?
Assumptions: four individual 0.6 × 1.2 m windows (23.6 × 47.2 in each) compared with one 1.2 × 2.4 m window (47.2 × 94.5 in), each layout totalling 2.88 m² (31.0 ft²). Use an 80 mm (3.15 in) projected frame-and-sash width, Uf 1.8 W/(m²·K), Ug 1.1 W/(m²·K), 6 mm panes, 13 mm glass bite and 3 mm secondary-seal back cover, with a comparable thermally broken metal frame. Assume argon filling with the stated Ug held fixed.
The 13 mm bite and Uf 1.8 satisfy BF's metal-frame requirement of Uf ≥ 1.3 at that bite. The stated double-glazing Ug also meets the ≥1.0 application condition.
BF section 4.3 allows the window-card values for double glazing with Ug ≥ 1.0 W/(m²·K) and argon or air filling. Use a comparable frame with at least 13 mm glass bite and the corresponding Uf condition. The glazing edge must be enclosed by the frame. Regular window cards use 3 mm secondary-seal back cover; facade cards use 6 mm. A free external glass edge requires a different calculation.
Each small window has glass area Ag 0.4576 m², frame area Af 0.2624 m² and glass-edge length lg 2.96 m. The large window has Ag 2.3296 m², Af 0.5504 m² and lg 6.56 m. Thus the four small windows have more total glass edge within the same overall opening area.
Calculate Uw = (Ag × Ug + Af × Uf + lg × ψg) / (Ag + Af). Apply the two corrected ψg inputs while holding each layout's other inputs constant.
At equal total window area, the spacer change reduces calculated Uw by 0.132 W/(m²·K) for the four small windows and 0.073 W/(m²·K) for the single large window.
| Window layout | Total glass edge | Uw with stainless reference | Uw with composite reference | Uw reduction, W/(m²·K) |
|---|---|---|---|---|
| Four 0.6 × 1.2 m windows | 11.84 m / 38.85 ft | 1.659 | 1.528 | 0.132 |
| One 1.2 × 2.4 m window | 6.56 m / 21.52 ft | 1.402 | 1.329 | 0.073 |
How should a UK project use the spacer result?
Put the calculated result beside the sizes and opening types in the UK window specification. The Part L window U value guide covers the project's applicable energy route.
Frame insulation remains a separate design input. Use the thermal-break strip selection and the thermally broken aluminium solution when selecting that part of the assembly.
What changes at the room-side glass edge?
Reducing junction heat loss helps keep the room-side edge warmer in winter. Indoor humidity and room-air movement determine how close that surface comes to the dew point. Follow the condensation location diagnosis when assessing moisture on the room side, outdoors or between panes.
Compare cavity gas and coating while retaining the same spacer and seal construction. The argon comparison gives a matched glass calculation.
FAQ
Can black spacer colour identify a low-psi construction?
For BF’s reference thermally broken metal frame with 4/16/4 double glazing and Ug 1.1 W/(m²·K), the cited stainless-steel and SAN-GF/foil examples give ψg 0.068 and 0.036 W/(m·K), respectively. Use the selected spacer’s junction data and reference construction for thermal selection. Spacer colour is an appearance choice.
Why can a stainless-steel spacer qualify as warm edge?
The thin-stainless-steel spacer in the cited BF reference card uses a 0.18 mm wall. Its thin cross-section meets the thermally improved construction category used for the published window-junction data.
Which correction applies when both glass panes are 6 mm thick?
Relative to the 4 mm reference panes, add 0.006 W/(m·K) to ψg for the stated two-pane construction, using 0.001 per extra outer-pane millimetre and 0.002 per extra inner-pane millimetre.
Let YULUX review your drawings before pricing.