Glass Daylight Opening vs Cut Size and the Glazing Dimension Chain
Daylight opening is the visible glass area; finished glass extends behind the frame by its edge cover. In the worked geometry below, a 1,000 × 1,400 mm daylight opening becomes 1,026 × 1,428 mm finished glass after the stated pocket depths and clearances are applied. Use the actual system section to set those allowances.
Which reference points define the glass dimension chain?
Use 3 horizontal or vertical references on the glazing section, the visible sightline, the glass edge and the bottom of the glazing pocket. Edge cover spans the sightline to the glass edge. Edge clearance spans the glass edge to the pocket bottom. Label both at each edge of the panel.
The structural rough opening belongs to the window installation drawing. The glazing pocket belongs to the sash or fixed frame. Follow the frame and rough-opening measurement guide when the project starts with a wall opening, then establish the glass dimensions from the selected system section.
| Drawing term | Reference to measure | Use in the order |
|---|---|---|
| Daylight opening, DLO | Visible width and height between sightlines | Appearance and clear glazed area |
| Finished glass size | Outer glass edges after the agreed processing stage | The width and height supplied |
| Edge cover or bite | Sightline to glass edge | Concealed overlap at each edge |
| Edge clearance | Glass edge to pocket bottom | Space around the glass perimeter |
| Face clearance | Glass face to adjacent groove surface | Accommodation across the glass thickness |
How do you calculate finished glass size from DLO?
For rectangular captured glazing, add 2 specified edge-cover allowances to each DLO dimension, left plus right for width and top plus bottom for height.
The same dimension can be obtained from the pocket-bottom opening. Subtract the clearances at its opposing edges. At a single edge, pocket depth equals edge cover plus edge clearance. These relationships connect the visible geometry to the concealed glazing detail.
A rectangular, captured panel has a DLO of 1,000 × 1,400 mm, approximately 39.370 × 55.118 in. Left and right pocket depths are 18 mm each, with 5 mm edge clearance each. Top and bottom pocket depths are 20 mm each, with 5 mm clearance at the top and 7 mm at the bottom. The dimensions are selected solely for this geometry exercise. If 5 mm is mistakenly deducted from both 1,000 mm DLO edges, the resulting 990 mm pane is 36 mm narrower than the correct 1,026 mm pane.
| Axis | DLO plus edge cover, mm | Pocket opening minus clearance, mm | Finished dimension, mm |
|---|---|---|---|
| Width | 1,000 + 13 + 13 | 1,036 − 5 − 5 | 1,026 |
| Height | 1,400 + 15 + 13 | 1,440 − 5 − 7 | 1,428 |
Two routes to the same finished glass size
Why must head, sill and jamb allowances be calculated separately?
In the example, increasing the bottom clearance from 5 to 7 mm uses 2 mm of the available pocket depth. Bottom cover becomes 13 mm while top cover remains 15 mm. The overall glass height follows those individual values.
The section also needs to place the setting blocks and relate their support position to the panel. Glass bite and setting-block hardness, size, length and location relative to glass width are included in section F of NGA's shop-drawing guidance.
A larger finished pane increases cover but reduces the remaining clearances. A smaller pane does the reverse. Manufacturing tolerances, frame tolerances and the support arrangement must therefore be considered together when approving the selected dimensions.
Why the top and bottom cover differ
Does a 2 mm groove gap mean deducting 2 mm from each glass edge?
In a glazing detail with at least 2 mm, about 0.079 in, face clearance, centre the glass in the groove and dimension the inner and outer gaps separately.
Allow movement gaps at the sides, top and bottom, and calculate the glass dimensions from the sash, or from the frame for a fixed light. Face clearance runs through the glass thickness. The side and end clearances enter the width and height equations separately. Compare the face and edge clearance directions in this Glazing installation detail.
On a section drawing, place the face-clearance arrows across the thickness and the edge-clearance arrows along the pane. This keeps the two sets of measurements legible during a bilingual drawing review. Use separate columns for them when translating a fabrication schedule.
The specification row for a finished glass order
Add a panel identifier, quantity, width-first orientation and units. For patterned or coated glass, show the viewing direction and surface orientation. For an insulating unit, use the agreed finished unit dimensions and separately record the pane-and-cavity construction. The 5–20A–5 glazing guide explains that construction notation.
Keep millimetres as the fabrication basis when the approved drawings use millimetres. Rounded inch conversions support reading the schedule. The window-schedule guide links each glass item back to its window mark and opening type.
FAQ
Is glass normally larger than its daylight opening?
In captured glazing, the glass extends behind the frame by the specified edge cover. Adding the two opposing cover dimensions to the DLO gives the corresponding finished glass dimension.
Can one deduction be used for every aluminium window system?
Use the 4 edge details of the selected system. Pocket depths, cover and clearances can differ between systems and between the head, sill and jambs of one assembly.
Does cut size always mean the finished insulating-glass size?
The order must name the process stage. Record the finished unit width and height for supply, and identify any separate raw-pane cutting or edge-finishing dimensions on the fabrication documents.
Let YULUX review your drawings before pricing.
Send us your window schedule, floor plans or photos. We review opening sizes, system direction, glass, hardware, finish and packing scope before quoting.