SANS 10400 XA Windows, Whole-Window U-Values and Glazing Choices

Read XA window-area bands, whole-window calculations, Part O lighting and ventilation, Part N safety glazing and the link to SANS 613.

Shaded strip windows on a stone-and-plaster residence in a dry hillside landscape.
Answer in brief

SANS 10400 XA Windows, Whole-Window U-Values and Glazing Choices

Under SANS 10400-XA:2021 Table 4, vertical fenestration up to 20% of each storey's nett floor area can use any U-value and SHGC within that table's first band. Above 20% and up to 25%, the maximum whole-window U-value becomes 5.20 W/(m²·K), with separate solar-gain limits by orientation and shading. Count the frame area in the fenestration total.

The details behind the answer

SANS 10400-XA:2021 original text, Table 4 and section 5.3

2021 Table 4 limits for vertical fenestration

Fenestration/nett floor area (%)Whole-window U max (W/m²K)W/NW/N/NE/E SHGC max, qualifying shadeW/NW/N/NE/E SHGC max, no qualifying shadeSW/S/SE SHGC
≤20AnyAnyAnyAny
>20–255.200.660.49Any
>25–304.400.530.44Any
>30–353.800.490.40Any
>35–403.300.440.35Any
>40–453.000.400.33Any
>45–502.600.350.30Any
>50–552.400.330.28Any
>55–602.200.300.25Any
>602.000.280.22Any

Where does the 20% window rule apply?

The International Energy Agency identifies the 2021 policy as in force in its published policy record. Regulation XA covers specified occupancies and extensions requiring submitted plans, including houses, flats and offices.

Calculate the ratio for each storey using its nett floor area and the external fenestration area, including framing. A drawing with several small rooms still needs a storey calculation. Roof lights have their own provisions in clause 5.3.8. A roof opening therefore needs an identified calculation line when assembling the glazing schedule.

SANS 10400-XA:2021 Table 4 and clauses 5.3.1–5.3.5 provide the calculation basis. The table covers every ratio band. The SW/S/SE group retains the U-value limit while its SHGC column accepts any solution.

How does changing one window affect the storey calculation?

Use one area total to select the ratio band, then calculate each orientation group with its own window areas. A large high-performance opening contributes more to that group average than a small opening with the same rating.

For this worked example, assume 100 m² of nett floor and 30 m² of vertical fenestration, comprising 20 m² facing W/NW/N/NE/E and 10 m² facing SW/S/SE. In the first group, 12 m² has whole-window U=3.0 and SHGC=0.35, while 8 m² has U=5.2 and SHGC=0.55.

The first group averages U=(12×3.0 + 8×5.2) ÷ 20 = 3.88 W/(m²·K) and SHGC=(12×0.35 + 8×0.55) ÷ 20 = 0.43.

For a 30% storey ratio, Table 4 limits U to 4.40 W/(m²·K) and unshaded W/NW/N/NE/E SHGC to 0.44.

Moving 4 m² from the lower-gain option to the higher-gain option changes the first group's SHGC to 0.47 while its total area remains the same. This exceeds the unshaded limit and fits the qualifying-shaded limit.

Clauses 5.3.4–5.3.5 require independent results for the two orientation groups and each storey. Calculate the southern group separately before reaching a building-level decision.

Change to the assumed first groupU average (W/m²K)SHGC averageResult against its selected limits
Base 12 m² + 8 m² split3.880.43Fits the unshaded 30% row
Move 4 m² to the higher-gain option4.320.47Solar average exceeds 0.44
Keep that revised split and add qualifying shading4.320.47Solar average is below shaded limit 0.53
A shift in glazing changes the group SHGC. Base 12 + 8 m² split: Area-weighted SHGC = 0.43; Shift 4 m² to higher gain: SHGC rises to 0.47, above the unshaded 0.44 example limit.
IMAGE NOTE

A shift in glazing changes the group SHGC

When can shading reduce the glazing upgrade cost?

At the 30% ratio, qualifying shading changes the first orientation group’s SHGC ceiling from 0.44 to 0.53. This can make an external shading proposal worth pricing alongside a glass change. Clause 5.2 defines the geometry, including projection and side extension. Its alternative external-device route includes an 80% summer-solar-radiation restriction by area.

Treat shade as a dimensioned building component. A narrow eave over a tall opening and a deeper canopy over a short opening cast different shadows. Position, projection and the distance to the bottom of the glazing all matter. The contractor’s drawing should therefore preserve the geometry used for the selected shading route.

South Africa’s energy zones inform the wider design. Table 4 itself uses area and orientation/shading columns. In the Southern Cape Condensation Problem Area, clause 5.3.6 requires a solution other than single-pane Low-E for achieving the U-value.

SHGC ceiling with and without qualifying shade. Unshaded: 0.44: first orientation group at 30% fenestration ratio; Qualifying shade: 0.53 for the same group and ratio.
IMAGE NOTE

SHGC ceiling with and without qualifying shade

Which glass and frame specification should a South African buyer compare?

Whole-window performance combines glass, frame and edge contributions. For an aluminium opening, changing the frame section can alter the result even when the glass construction stays identical. NGA’s energy paper explains these contributions and the effect of coatings, gas and spacers.

Chongqing’s 2023 thermal-parameter catalogue lists 6 mm single-silver Low-E + 12A + 6 mm clear glass at Ug=1.72 W/(m²·K). Its 12Ar version with an automatically sealed warm-edge system is listed at Ug=1.44. Both constructions total 24 mm, approximately 0.945 inches.

The argon version also changes the spacer system. Use the complete coating, gas and edge construction in the whole-window calculation.

XA clauses 5.3.2–5.3.3 use ANSI/NFRC 100 for total U-value and ANSI/NFRC 200 for SHGC. Keep the glass-only Ug entries in the Chinese catalogue distinct from those whole-window fields. SANS original text, section 5.3

Can clear single-glazed aluminium windows meet XA above 20%?

SANS 10400-XA Annex E, Table E.1 gives an indicative whole-window U-value range of 5.5–7.9 W/(m²·K) for clear single glazing in metal framing. Even the low end exceeds Table 4’s first limit above 20%, U≤5.20. An all-clear-single-glazed metal-frame package therefore falls outside that elemental band.

Coated single glazing has a different indicative range. The pane treatment, frame and area-weighted result determine the selected option. The approved design route establishes how the complete building is assessed.

How do Part O, Part N and SANS 613 affect the same window?

SANS 10400-O:2011 clause 4.2.1.1.3 requires natural-light openings, including frames and glazing bars, of at least 10% of room floor area or 0.2 m², whichever is greater, for its general building category. It gives 5% for Category 1 buildings in occupancies F2, H3 and H4.

For direct natural-ventilation openings, clause 4.3.1.1.3 uses 5% of room floor area, or the applicable minimum of 0.1 m² for specified Category 1 occupancies and 0.2 m² for other buildings, whichever is greater. The openable area belongs in the room schedule alongside glazed area.

SANS 10400-N:2012 clause 4.4 requires safety glazing compliant with SANS 1263-1 in specified locations, plus permanent visible marking of individual safety panes. Doorways, low sills and circulation routes affect that selection.

XA clause 5.3.7 requires window and door maximum air leakage to comply with SANS 613. The mechanical-performance standard also addresses wind action, water penetration and operation. The procurement schedule needs energy performance, safe glazing and the relevant mechanical rating.

What should a South African window quote list?

Quotation fieldDetail
Area and locationStorey, dimensions, nett floor area and orientation group
AssemblyFrame, sash layout, glass construction, gas and spacer
EnergyWhole-window U-value, SHGC and calculation method
ShadingProjection, position and qualifying geometry
Safety and mechanicsPart N glazing and SANS 613 performance
OptionsOpening codes, quantities and priced configuration changes

FAQ

Is the SANS 10400-XA glazing threshold 15% or 20%?

The 2021 second-edition Table 4 uses 20% for its first vertical-fenestration U/SHGC band. Older 15% guidance describes the previous framework.

Must every South African house have double glazing?

The 2021 method selects performance using the window-area ratio and assembly ratings. The Southern Cape Condensation Problem Area also has a specific restriction on using single-pane Low-E to achieve U-value.

Can a good upstairs window average offset a poor ground floor?

Each storey and each of the 2 orientation groups must satisfy its applicable limits independently under clauses 5.3.4–5.3.5.

Does meeting XA also satisfy safety-glazing requirements?

The window schedule also needs the applicable Part N safety-glazing selection, Part O lighting and ventilation, and SANS 613 performance. Each requirement has its own assessment.

HAVE A PROJECT SCHEDULE?

Let YULUX review your drawings before pricing.

Send us your window schedule, floor plans or photos. We review opening sizes, system direction, glass, hardware, finish and packing scope before quoting.

Continue planning your window and door project

Dimensions, loads and building standards

Get a Quote

Share your window schedule, architectural drawings, opening sizes or a project brief. We'll reply with system, glass, hardware, finish and export packing recommendations.

YULUX chat

AI assistant · Human support
⋯

AI guidance only; our team confirms pricing. ·

I am an AI, not a person. Share non-sensitive project needs only. Answers and search sources need verification; I cannot confirm pricing, agency status or contracts. The temporary session is kept in this browser tab and server memory, and clears after 30 minutes of inactivity. Privacy policy

Hi, I’m YULUX’s AI assistant. Ask about products, window and door systems, or partnership.