Send drawings

Selection comparison

Aluminium Framed Shower Screen Options for Hotel and Apartment Projects

Compare framed, semi-frameless and frameless shower screens by glass thickness, price tier, door clearance, safety requirements and hotel procurement.

Clear glass shower enclosure with a slim dark aluminium corner frame and tiled wall.
Answer in brief

Aluminium Framed Shower Screen Options for Hotel and Apartment Projects

Shower-screen thickness follows the edge support and panel width. For fixed unframed toughened-glass panels continuously supported in channels along the wall and floor, WGANZ's 2022 model recommends widths up to 750 mm for 8 mm glass and 1500 mm for 10 or 12 mm glass. Use the model's loading and deflection assumptions below when applying those recommendations. WGANZ fixed-screen bulletin

Which shower-screen style fits a hotel refurbishment budget?

Published examples use 5–6 mm glass for fully framed screens and 6 mm for semi-frameless screens, while WGANZ models 8, 10 and 12 mm fixed unframed panels with continuous wall-and-floor channel support. For repeat hotel rooms, start with standard-size framed screens, whose published 5–6 mm configurations are the lower-cost option compared with custom frameless assemblies. Repeated hotel room layouts favour that option when the standard dimensions fit. WGANZ Glass in Showers

Fully framed glass has protected edges and more channels to clean. Semi-frameless layouts support fixed panels while exposing more of the door edge. The examples in the table come from the named product ranges. Just Glass shower types Avanti framed system Avanti semi-frameless system

ArrangementPublished configuration exampleHotel selection and trade-off
Fully framedJust Glass describes 5 mm and Avanti 6 mm framed optionsChoose standard room sizes for lower-cost framed construction, with extra channels to clean
Semi-framelessAvanti and Ready Glaze list 6 mm optionsChoose reduced door framing with supported fixed panels
Fixed unframedWGANZ models 8, 10 and 12 mm panels under stated channel supportChoose less visible framing within the width and load limits, with heavier glass

How wide can a fixed frameless panel be?

Its model uses monolithic toughened glass continuously supported in channels at the wall and floor, a 200 N horizontal load at 1750 mm above the base, and an assumed 50 mm maximum free-edge deflection. These correspond to approximately 45 lbf, 68.9 inches and 2 inches.

Moving doors need their own hinge or roller capacity and fixing design. Final glass dimensions and supports must satisfy the destination's rules and the selected assembly's engineering limits.

Width limits in the WGANZ fixed-screen model. Support assumed: Monolithic toughened glass in continuous wall and floor channels.; 8 mm glass: Recommended maximum panel width 750 mm.; 10 or 12 mm glass: Recommended maximum panel width 1,500 mm under the same assumptions..
IMAGE NOTE

Width limits in the WGANZ fixed-screen model

Will a sliding, hinged or pivot door clear the basin?

Plot the moving leaf, handle and usable entrance on the finished bathroom plan. A slider keeps movement inside the enclosure. A hinge needs space outside it, while an inset pivot sweeps on both sides of its axis.

Assumptions for the layout calculation are a 1200 mm clear recess, two equal bypass panels overlapping by 50 mm, alternative 600 mm doors, a 75 mm inset pivot, and 520 mm clearance to the basin, before hardware deductions.

The slider gives a nominal 575 mm entrance, approximately 22.6 inches. Both assumed swinging arrangements clash with the basin. A larger recess or different panel arrangement may be needed for assisted access.

ArrangementCalculationResult
Bypass sliderPanel = (1200 + 50) ÷ 2 = 625 mmEntrance = 1200 − 625 = 575 mm
Edge-hinged doorSweep = 600 mm80 mm beyond the 520 mm clearance
Inset pivotMain sweep = 600 − 75 = 525 mm5 mm beyond clearance, plus 75 mm reverse sweep
Door travel beside a basin 520 mm away. Bypass slider: In the 1,200 mm recess, a 50 mm overlap leaves a nominal 575 mm entrance.; Edge hinge: The 600 mm door overshoots the basin clearance by 80 mm.; Inset pivot: A pivot inset 75 mm leaves a 525 mm main sweep, 5 mm too long..
IMAGE NOTE

Door travel beside a basin 520 mm away

Which safety-glass documents apply to the destination?

The US 16 CFR 1201 puts shower doors and enclosures in Category II, including panels below 9 square feet. Section 1201.4 incorporates ANSI Z97.1-2015 test provisions. Include permanent manufacturer and safety-standard identification in the purchase specification and verify it against the approved glazing schedule.

The Australian AGWA compliance guide calls for Grade A safety glass and glazing to AS 1288, alongside AS 3740 water-stop and waterproofing details.

For Britain, BS EN 14428 addresses enclosure functionality and testing. BS EN 12150 covers thermally toughened soda-lime silicate safety glass, while BS EN 12600 covers pendulum-impact testing and classification.

Canada's Glass Doors and Enclosures Regulations set safety-glass tests and require the responsible importer to keep compliance documents for at least 4 years after import.

DestinationGlazing or assembly requirementProject document
United States16 CFR 1201 Category II, ANSI Z97.1-2015 test provisionsSafety test and certification documentation
AustraliaGrade A glass, AS 1288, AS 3740 interfacesGlazing schedule and waterproofing detail
BritainBS EN 14428, BS EN 12150, BS EN 12600Enclosure performance and glass classification
CanadaSOR/2016-174 safety-glass requirementsImporter compliance file retained 4 years

What should a Chinese glass factory document before shipment?

China's CNCA-C13-01:2026 safety-glass rule requires permanent CCC identification on ordinary certified safety glass and a factory code beside the mark. Annex 7 schedules tempered-glass fragmentation checks once per shift and when product type or thickness changes, impact checks once every half-year, and bending-strength checks once per year.

The same annex assigns routine thickness, appearance, dimensions and bow checks to GB/T 15763.2. The current GB/T 15763.2-2025 official record gives 1 August 2026 as its implementation date. Put the applicable edition and glass identification on the purchase schedule.

For fittings, 304 is a candidate for ordinary indoor service and 316 merits evaluation where chloride exposure is significant. The Chinese-language worldstainless materials guide explains that molybdenum in 316 improves resistance to chloride-related pitting and crevice corrosion. Specify the alloy of the hinge body, pins and screws individually.

How should the project plan packing, spares and maintenance?

A project packing specification can use padded upright wooden crates or engineered A-frame racks, with separated glass faces, protected corners and restrained hardware cartons. Match the rack's unloading method and load rating to the receiving site. Keep crate identification tied to the room and panel schedule.

For a purchase-planning allowance of 100 identical rooms, ordering 2 spare moving panels and 2 compatible hardware kits gives 102 panels and 102 kits. The spare allowance is 2% of installed quantity. Different left- and right-hand layouts need separate stock decisions.

Water control starts with spray direction, door gaps, bottom seals and floor fall. Keep the designed drainage outlets open and tracks clear. Local installation and maintenance belong in the hotel contract, with replacement parts stored where staff can find them.

FAQ

Does a semi-frameless shower screen need 8 mm glass?

Avanti and Ready Glaze publish 6 mm semi-frameless screen options. Select the specific assembly by panel size, support and its hardware. Avanti semi-frameless screens Ready Glaze semi-frameless screens

What clear entrance does a 1200 mm bypass shower provide?

575 mm is the nominal entrance with 2 equal panels and a 50 mm overlap, before handles, seals and stops reduce the opening.

Should coastal hotel shower fittings use 304 or 316?

316 offers greater resistance to chloride-related pitting and crevice corrosion because it contains molybdenum. Include cleaning chemistry and the alloy of screws and pins in the hardware selection.

How many spare panels should a 100-room hotel order?

2 spare panels provide a 2% allowance for a project with 100 identical installed panels. Price that purchasing option by panel type, handing and replacement lead time.

HAVE A PROJECT SCHEDULE?

Let YULUX review your drawings before pricing.

Send us your window schedule, floor plans or photos. We review opening sizes, system direction, glass, hardware, finish and packing scope before quoting.

Continue planning your window and door project

Window, door and material selection

Get a Quote

Share your window schedule, architectural drawings, opening sizes or a project brief. We'll reply with system, glass, hardware, finish and export packing recommendations.

YULUX chat

AI assistant · Human support
⋯

AI guidance only; our team confirms pricing. ·

I am an AI, not a person. Share non-sensitive project needs only. Answers and search sources need verification; I cannot confirm pricing, agency status or contracts. The temporary session is kept in this browser tab and server memory, and clears after 30 minutes of inactivity. Privacy policy

Hi, I’m YULUX’s AI assistant. Ask about products, window and door systems, or partnership.