Aluminium vs uPVC Windows for Cost, Frame Width and Hot Climates
For clear, air-filled double glazing in hinged/projected windows, NSW's planning defaults give Uw 3.0 W/(m²K) for its timber/uPVC/fibreglass group and 3.6 W/(m²K) for thermally broken aluminium. These grouped planning defaults provide a comparison under the stated glazing and opening conditions. Select the quoted window using its whole-window rating, complete sightline and load-specific dimensions. NSW default configurations
What changes inside the frame cross-section?
An aluminium section carries loads through its metal walls, with a structural polymer separating the inside and outside halves. A uPVC section uses hollow chambers, seals and reinforcement selected for the sash. The glass edge, opening seal and wall fixing connect these parts into a working window.
One Chinese component manufacturer's catalogue includes 14.8 and 24 mm thermal-break strips. These are component widths for use within a designed aluminium section.
Which frame configuration fits your budget and site?
| Buyer priority | Thermally broken aluminium | uPVC |
|---|---|---|
| Purchase price | Higher in FMB’s UK guide, at £800 for a 900 × 1,200 mm casement. | Lower in the same UK guide, at £615 for a 900 × 1,200 mm casement. |
| Whole-window insulation | NSW’s clear/air-filled hinged default is Uw 3.6 W/(m²K). | NSW groups it with timber/fibreglass at Uw 3.0 W/(m²K) for that glazing and operation. |
| Visible face | Published concealed-vent aluminium example, minimum 67 mm | Published uPVC frame-and-sash example, 117–144 mm |
| Moving sash examples | Separate aluminium system, up to 160 kg with alternative formats 1,700 × 2,100 or 1,000 × 2,500 mm | The cited uPVC system, up to 130 kg with load-specific dimensions |
| Published acoustic ceiling | The separate aluminium system, up to 48 dB sound insulation for specified assemblies | The cited uPVC system, Rw up to 47 dB under EN ISO 717-1 for specified assemblies |
| Hot, dark elevations | The 2 m calculation below gives 1.41 mm free expansion for a 30°C rise. | The same calculation gives 3.60 mm, increasing the importance of colour-specific reinforcement and clearances. |
Frame construction schematic showing a thermal break beside a reinforced hollow uPVC profile.
How narrow can the frame be, and how large can the sash go?
A published concealed-vent aluminium example has a minimum visible face of 67 mm, while a separate uPVC system lists a frame-and-sash face of 117–144 mm. These are different section designs, measured across the visible face toward the glass. Compare complete visible sections for the proposed opening arrangement.
A separate published aluminium system lists a maximum sash mass of 160 kg with alternative formats of 1,700 × 2,100 mm or 1,000 × 2,500 mm, while the cited uPVC system lists 130 kg per sash with load-specific sizing. Keep each published width-height pair and its mass limit together. The aluminium load example and the concealed-vent sightline example use different section designs.
The cited aluminium system advertises sound insulation up to 48 dB, while the cited uPVC system states Rw up to 47 dB under EN ISO 717-1 for its specified assemblies. Each catalogue ceiling depends on its glass and seals. Comparing the two requires matching the acoustic metric, test method and complete assembly.
For ventilation with a broad view, combine a fixed pane with a smaller opening leaf. The awning, casement and sliding schedule guide compares those layouts.
Will dark uPVC windows move more in strong sun?
With a uniform 30°C rise over 2,000 mm, free expansion is 1.41 mm for 6063 aluminium and 3.60 mm for PVC-U.
The calculation assumes straight, unrestrained members with uniform bulk temperature and the published material coefficients.
Dark PVC-U profiles absorb more solar heat, so their bulk temperature can exceed air temperature. Reinforcement restrains movement, and colour-specific expansion clearances accommodate the remainder. Large dark sashes therefore need the profile supplier’s hot-climate size and reinforcement schedule. Infrared-reflecting films can reduce heat buildup.
For heat-flow modelling, the association reference uses 160 W/(m·K) for painted aluminium-silicon alloy, 0.17 for rigid PVC and 0.30 for glass-fibre-reinforced PA66. These are modelling inputs. Whole-window Uw includes the glass and edges as well as the frame. Material reference, Appendix D
| Member | Expansion calculation | Length increase |
|---|---|---|
| 6063 aluminium | 23.5 × 10⁻⁶/K × 2,000 mm × 30 K | 1.41 mm |
| PVC-U | 60 × 10⁻⁶/K × 2,000 mm × 30 K | 3.60 mm |
The example holds starting length and temperature rise constant and allows both members to expand freely.
Does an Australian BAL rating restrict the frame material?
AGWA’s BAL-29 provisions include qualifying metal-reinforced uPVC, while the BAL-40 prescriptive window route requires metal frames.
Under AS 3959 clause 1.5.22, the qualifying uPVC assembly needs a continuous metal frame that keeps supporting the glass and limits resulting gaps to 2 mm if the polymer falls away.
At BAL-29, AGWA’s prescriptive window route specifies at least 5 mm toughened glass, screening of openings and external protection of low-level glazing. At BAL-40 it specifies at least 6 mm toughened glass and external screens over fixed and opening portions, using corrosion-resistant steel or bronze mesh with apertures no larger than 2 mm. For double glazing, the glass requirement applies to the outer pane.
AGWA also describes tested-system and bushfire-shutter routes. The selected assembly must follow its applicable route, including seals and hardware. AGWA bushfire guide, p5 and BAL-29/BAL-40 window sections
Unrestrained material expansion from published coefficients.
Select the configuration for each elevation
AGWA recommends hardware maintenance every 6 months generally and every 3 months in marine or industrial exposure. Clear drainage slots, reseat displaced seals and service the locking points. Hardware maintenance guidance
FAQ
Which is cheaper, aluminium or uPVC windows?
FMB’s November 2026 UK guide lists a 900 × 1,200 mm casement at £615 in uPVC and £800 in aluminium. The tables leave labour and VAT inclusion unspecified. Compare supply, installation and finish on the same schedule. FMB price guide
Which lasts longer, aluminium or uPVC windows?
For lifespan budgeting, a 2024 peer-reviewed case study uses 30 years for both PVC and aluminium frames. Component quality, exposure and replacement seals determine the actual service period. Study, Table 9
Are aluminium frames better for large dark windows?
In the stated 2,000 mm unrestrained-member calculation, a 30°C rise lengthens 6063 aluminium by 1.41 mm and PVC-U by 3.60 mm. For a dark sash, use the actual system's reinforcement and expansion clearances alongside its glass mass and size limits.
Can uPVC windows be used in a BAL-29 area?
Yes, through an applicable AS 3959 route, including qualifying metal-reinforced uPVC with continuous glass support and gaps limited to 2 mm after loss of the polymer. AGWA guidance
Let YULUX review your drawings before pricing.
Send us your window schedule, floor plans or photos. We review opening sizes, system direction, glass, hardware, finish and packing scope before quoting.