Send drawings

Standards explained

Title 24 Window Requirements for California Homes in 2026

Choose California windows by 2025 code scope, 2026 permit date, climate zone and whole-product ratings, with a worked area-weighted example.

Shaded aluminium windows on a low-rise California-style residence in bright sun.
Answer in brief

Title 24 Window Requirements for California Homes in 2026

For California single-family homes under the 2025 Energy Code, new-construction prescriptive U-factor limits are 0.27 in Climate Zones 1–5, 11–14 and 16, and 0.30 in Zones 6–10 and 15, in Btu/(h·ft²·°F). The Zone 5 small-dwelling exception and separate replacement limits are set out below. The code applies to permit applications submitted on or after January 1, 2026.

The details behind the answer

Does a 2026 permit use the 2025 code?

This article covers single-family housing. Put the project climate zone and the permitted work description beside the window schedule before choosing glass. A new house, an extension and replacement windows in an existing wall can produce different allowable schedules at the same address.

Start with the California permit application date. Permit application: Find the submission date in the project file; From 1 January 2026: Applications from this date start under the 2025 Energy Code.
IMAGE NOTE

Start with the California permit application date

Which limits belong on a new-home window schedule?

Section 150.0(q) sets a mandatory maximum area-weighted U-factor of 0.40 for applicable fenestration, subject to its exceptions. Meeting that baseline still leaves the selected compliance path to satisfy. CEC mandatory fenestration guidance

A new dwelling in Climate Zone 5 with conditioned floor area of 500 ft² or less may use U-factor 0.30. Read the table below with that exception. CEC Table 3-2 and footnote

Climate zonesMaximum U-factorMaximum SHGC
1, 3, 5, 160.27, subject to Zone 5 exceptionNo prescriptive SHGC limit
2, 4, 11–140.270.23
6–100.300.23
150.300.20

The prescriptive new-home package also limits total fenestration to 20% of conditioned floor area, with a west-facing limit of 5% in Zones 2, 4 and 6–15. A package can meet U-factor and SHGC yet exceed its allowed area. CEC Table 3-2

What changes when the work is replacement or an addition?

In Climate Zone 15, new single-family construction has a prescriptive area-weighted SHGC ceiling of 0.20, while vertical replacement windows use 0.35 for up to 75 ft² and 0.23 above 75 ft². The replacement threshold includes exactly 75 ft² in the smaller-area category. CEC Summer 2026 clarification

For up to 75 ft² of vertical replacement fenestration, the exception allows U-factor 0.40 in all climate zones and SHGC 0.35 in Zones 2, 4 and 6–15. Above that area, use the applicable replacement prescriptive U-factor schedule, including 0.27 in Zones 1–5, 11–14 and 16, and 0.30 in Zones 6–10 and 15. CEC Chapter 9, Examples 9-25 and 9-27

Classify enlargement separately. CEC treats replacement within the same existing wall or roof by comparing installed and removed fenestration area. Additional net glazing enters the new-fenestration category. Enlarging a bedroom opening into a glazed door can therefore create both replacement and added area in one purchase. CEC alteration classification note

An addition creates its own conditioned-floor-area calculation. For a prescriptive addition of up to 400 ft², the total glazing allowance is the greater of 75 ft² or 30% of its conditioned floor area. Larger additions follow other bands, together with applicable orientation and thermal limits. Keep extension windows in the addition calculation when pricing a combined renovation order. CEC Table 9-3

Can an area-weighted schedule keep the larger view window?

Area weighting measures the contribution of each opening to the complete eligible schedule. Dividing by the number of windows would give a small bathroom unit the same influence as a large picture window. The CEC permits area-weighted U-factor and SHGC assessment within the applicable compliance provisions. CEC Example 3-1

For this worked example, assume a new single-family home in Climate Zone 15 on the prescriptive route with 200 ft² of eligible vertical windows and all fenestration-area limits satisfied. The proposed groups have the whole-product ratings below.

Window groupAreaU-factorInitial SHGCRevised SHGC
View windows120 ft²0.320.220.18
Other windows80 ft²0.250.180.18

Weighted U-factor = (120 × 0.32 + 80 × 0.25) ÷ 200 = 0.292. The schedule meets the Zone 15 ceiling of 0.30 even though the view-window group individually has U-factor 0.32.

Initial weighted SHGC = (120 × 0.22 + 80 × 0.18) ÷ 200 = 0.204. That exceeds the new-home ceiling of 0.20. Revising the view-window group to SHGC 0.18 gives (120 × 0.18 + 80 × 0.18) ÷ 200 = 0.18, which meets that thermal criterion.

The original 0.204 would satisfy the 0.23 SHGC ceiling for a qualifying replacement project above 75 ft² in the same zone. The project classification therefore changes the purchasing decision. Carry the actual rated replacement configuration into the schedule, including any U-factor change caused by the glazing substitution.

Two opening groups in an area-weighted schedule. View windows: 120 ft² at U-factor 0.32; Other windows: 80 ft² at U-factor 0.25; Weighted result: (120 × 0.32 + 80 × 0.25) ÷ 200 = 0.292.
IMAGE NOTE

Two opening groups in an area-weighted schedule

Where does the performance path give design freedom?

The performance route evaluates the proposed building against an energy budget using CEC-approved compliance software. It can accommodate a design that exceeds a prescriptive component target when the complete modeled design passes and applicable mandatory measures are satisfied. CEC explanation of the compliance approaches

For an existing home, CEC identifies an Existing + Alteration route where prescriptive replacement requirements cannot be met. The energy designer must model the relevant existing and proposed conditions. CEC Example 9-28

Which Chinese quotation value belongs in the energy calculation?

NFRC ratings describe certified whole-product performance. Match the ordered opening type and glazing option to the whole-window U-factor and SHGC used in the energy documentation. NFRC whole-product rating explanation

Use the casement window configurations to identify the opening type, frame and glazing in your enquiry, and keep the required whole-product U-factor and SHGC beside each window mark.

If a timber interior finish is part of the design, compare the aluminium-clad wood window options using the same opening sizes and energy targets.

The Ningxia reference table lists glass Kg of 1.8 W/(m²·K) alongside whole-window K of 2.3 W/(m²·K) for one specified air-filled Low-E assembly. Its conditions include frame Kf of 2.7, an ordinary aluminum spacer and a thermal-break width of at least 20 mm. With argon, the listed glass and whole-window values become 1.6 and 2.2 respectively. Ningxia housing authority, Table B.0.4

Those Chinese reference values illustrate why a glass Kg entry cannot fill a California whole-product rating field. Preserve the units and rated construction when translating the quotation. CEC also provides applicable default-rating procedures, which the energy calculation must evaluate if that route is used. CEC Table 3-1

For a California window quotation, send the opening schedule, project location, permit scope and target U-factor and SHGC. List the whole-product evidence your project team needs to review.

Send your window schedule and energy targets on WhatsApp so we can discuss the proposed frame and glass configuration.

FAQ

Is the 75 ft² replacement allowance per window?

The 75 ft² threshold applies to the vertical replacement fenestration area covered by the provision. Add the affected openings when selecting the replacement category. CEC replacement-area clarification

Does an NFRC label by itself establish Title 24 compliance?

An NFRC label supplies whole-product ratings. The project still needs the applicable code edition, climate-zone limits, scope and compliance calculation matched to those ratings.

Does every window need the same SHGC?

Eligible windows can have different SHGC ratings when their area-weighted schedule meets the applicable limit. In Zone 15 new single-family prescriptive construction, that limit is 0.20.

HAVE A PROJECT SCHEDULE?

Let YULUX review your drawings before pricing.

Send us your window schedule, floor plans or photos. We review opening sizes, system direction, glass, hardware, finish and packing scope before quoting.

Continue planning your window and door project

Dimensions, loads and building standards

Get a Quote

Share your window schedule, architectural drawings, opening sizes or a project brief. We'll reply with system, glass, hardware, finish and export packing recommendations.

YULUX chat

AI assistant · Human support
⋯

AI guidance only; our team confirms pricing. ·

I am an AI, not a person. Share non-sensitive project needs only. Answers and search sources need verification; I cannot confirm pricing, agency status or contracts. The temporary session is kept in this browser tab and server memory, and clears after 30 minutes of inactivity. Privacy policy

Hi, I’m YULUX’s AI assistant. Ask about products, window and door systems, or partnership.