Aluminum Window Profile Thickness, Nominal Walls and kg/m
Aluminum window profile thickness under GB/T 8478-2020 has a 1.8 mm nominal minimum for exterior-window main-profile base metal and a 2.2 mm minimum for exterior-door main profiles. Fin walls at accessory functional grooves are excepted. For exterior load-bearing members, design calculations and testing determine the specified thickness alongside those minima. The official standard record identifies the Chinese product standard.
What does 70 series mean for wall thickness?
Under GB/T 8478-2020 clause 4.1.4, a 70 series frame has a 70 mm construction depth. This is approximately 2.76 inches. The GB/T 8478-2020 official standard record defines depth as measured at the frame section’s wall-connection side, using the largest depth when perimeter members differ. The local metal wall and the front-facing sightline each have their own dimensions.
Main profiles form the frame-and-sash skeleton, including joining members in combined windows. Glazing beads and drip profiles are supplemental components. Mark the frame, sash and mullion on the drawing so the thickness specification follows the intended member.
Compare the casement window frame and opening options, then mark the required wall thickness against the frame, sash and mullion sections in your enquiry drawing.
If your elevations call for grilles, review the French-style window and door systems alongside the section drawing, grille layout and opening directions.
The series depth spans the section; the base-metal dimension measures one local wall.
Which Chinese wall-thickness requirement applies?
Clause 5.1.2.1.2 gives interior windows a 1.4 mm nominal minimum and interior doors a 2.0 mm minimum. Its 1.8 mm exterior-window and 2.2 mm exterior-door values concern main-profile base metal, with the groove-fin exception. The standard covers manually operated building exterior-wall and internal-partition windows and pedestrian doors, plus vertical roof windows.
Major load-bearing members include transoms, mullions, sash members and joining frames that transmit selfweight and horizontal wind loads. Clause 5.1.2.1.1 requires their exterior main-profile nominal thickness to follow design calculation and testing. Supplemental beads and drip profiles have a different component role.
A 70 series frame and a 1.8 mm metal wall identify different dimensions of the same section.
How do 1.4, 1.6, 1.8 and 2.0 mm compare?
| Nominal wall | Against the 1.8 mm exterior-window floor | GB/T 8478-2020 interpretation |
|---|---|---|
| 1.4 mm | 0.4 mm below | Interior-window nominal minimum |
| 1.6 mm | 0.2 mm below | Below the exterior-window nominal minimum |
| 1.8 mm | Equals the floor | Exterior-window nominal minimum |
| 2.0 mm | 0.2 mm above | Additional metal within the same geometry |
How is base-metal thickness measured?
GB/T 8478-2020 clause 6.1.2.1 obtains base-metal thickness by subtracting the surface-treatment thickness from the total. It uses at least 5 points at the same type of location, expresses the base-metal result to 0.01 mm and takes the average. The coating instrument resolves 0.5 micrometres and the dimensional gauge resolves 0.02 mm or better.
A painted sample therefore needs coating and dimensional readings at identified locations. The aluminium window sample approval guide connects the section drawing to its finish, corner and assembly details.
What does the super-high-precision tolerance allow?
For mating main profiles, GB/T 8478-2020 clause 5.1.2.1.3 calls for the GB/T 5237.1 super-high-precision wall-thickness grade. Figure 2 of GB/T 5237.1-2017, Figure 2 and Table 2 identifies A as solid-wall thickness, B as the perimeter wall of a closed cavity, and C as the partition between closed cavities.
For 1.20–2.00 mm nominal walls and a circumscribed-circle diameter up to 100 mm, GB/T 5237.1-2017 Table 2 gives super-high-precision tolerances of ±0.09 mm for group A and ±0.10 mm for groups B and C, subject to its geometry notes.
For the same nominal range with a diameter over 100 mm through 250 mm, the A and B/C allowances become ±0.10 and ±0.12 mm. At 2.2 mm nominal and a diameter up to 100 mm, the table’s over-2.00-through-3.00 mm row gives ±0.09 mm for A and ±0.13 mm for B/C.
Table 2 also changes the selection for cavity geometry and opposing-wall thickness. A closed cavity smaller than 70 mm² uses group A allowances for its perimeter walls. Unequal opposing walls below a 3-to-1 ratio use their average thickness to select the allowance. A ratio of 3-to-1 or more requires supplier–buyer agreement. Identify the full section and applicable notes before calculating a measured acceptance range.
Ideal rectangular chambers compare wall thickness and depth at a stated density of 2.70 g/cm³.
How much weight does a thicker wall add per metre?
Assumptions: uniform-wall, sharp-corner rectangular hollow chambers, density 2.70 g/cm³, and bending about the centroidal axis parallel to width b. Width b, depth h and wall t are in millimetres. The University of Arizona section equations give metal area A = bh − (b − 2t)(h − 2t), and I = [bh³ − (b − 2t)(h − 2t)³] / 12.
Mass per metre equals A × 2.70 ÷ 1,000 in kg/m. Chinese extrusion suppliers publish weight-based quotations and use kg/m to convert a kilogram rate into a metre rate. Fabricated-window pricing additionally includes glazing, hardware, fabrication and finish.
For the same 40 × 60 mm rectangular hollow section, increasing the wall from 1.4 to 2.0 mm raises calculated section area by 41.1% and bending inertia by 38.1%. At 2.70 g/cm³, that 1.4-to-2.0 mm wall change raises calculated mass from 0.735 to 1.037 kg/m.
| Width × depth (mm) | Wall (mm) | Metal area (mm²) | Bending inertia (mm⁴) | Mass (kg/m) |
|---|---|---|---|---|
| 40 × 60 | 1.4 | 272.16 | 139,837 | 0.735 |
| 40 × 60 | 1.6 | 309.76 | 158,032 | 0.836 |
| 40 × 60 | 1.8 | 347.04 | 175,801 | 0.937 |
| 40 × 60 | 2.0 | 384.00 | 193,152 | 1.037 |
| 40 × 80 | 1.8 | 419.04 | 353,971 | 1.131 |
Can a deeper 1.8 mm profile be stiffer than a 2.0 mm profile?
A 40 × 80 × 1.8 mm hollow section has about 83.3% more bending inertia than a 40 × 60 × 2.0 mm section about the stated axis. Increasing depth moves material farther from the bending axis. For a long mullion, section depth can therefore make a substantial contribution to bending stiffness.
Real window extrusions include chambers, grooves and joints. Their calculated section properties must match those shapes. A thermal-break connection, corner joint and hardware mounting zone each contribute to the assembled behaviour. Compare alloy and temper as well as section geometry when matching two offers.
What does wall thickness tell me about insulation and security?
Within the same geometry, a thicker wall adds cross-sectional area and bending stiffness. At hinges and locks, specify screw engagement and reinforced fixing zones, then assess the assembled hardware and glazing retention.
Whole-window U-value includes heat transfer through glass, frames and edges. Compare the thermal break, glazing, spacer and frame dimensions at the same window size. Government glazing guidance · Thermal performance guide
For UK/European product assessment, BSI’s BS EN 14351-1 scope addresses material-independent performance characteristics of windows and external pedestrian doorsets. For North America, FGIA’s NAFS guidance covers wind structural, air, water and forced-entry requirements; its FAQ separately identifies NFRC 100 for thermal performance. Specify the destination project’s whole-window targets and matching tested configuration.
How do wind pressure and span complete the profile specification?
For an insulating-glass-supporting main member, GB/T 8478-2020 limits deflection at P3 to the lesser of L/150 and 20 mm. Here L is the support span, so a 1,500 mm span gives a 10 mm deflection limit. The design pressure and the selected assembly establish whether the window achieves that limit.
FGIA’s performance designation combines opening type, performance class, performance grade and tested size. Match the quoted dimensions and construction to the covered system. The wind, water and air report guide explains this report-to-configuration check.
For a window quote against your section and opening schedule, send the opening sizes, quantities, destination and marked profile drawing. Identify the members that need a specified wall thickness and include the project's wind-load requirements.
Send the section drawing and opening sizes on WhatsApp, marking which frame, sash or mullion thickness you want to compare.
FAQ
Is 1.4 mm aluminum thick enough for an exterior window?
GB/T 8478-2020 sets the exterior-window main-profile nominal minimum at 1.8 mm. Its 1.4 mm nominal floor applies to interior windows, with the specified groove-fin exception and other applicable requirements.
Is a 2.0 mm window profile always better than 1.8 mm?
For the same geometry, 2.0 mm adds area and bending stiffness. In the calculated chamber example, a deeper 40 × 80 × 1.8 mm section has 83.3% more bending inertia than 40 × 60 × 2.0 mm about the stated axis.
Does 70 series mean a 70 mm-thick aluminum wall?
70 series denotes a 70 mm frame construction depth under GB/T 8478-2020. The local base-metal wall has a separate dimension, such as 1.8 mm.
How do I calculate aluminum profile weight per metre?
Multiply metal cross-sectional area in mm² by density in g/cm³, then divide by 1,000. With 2.70 g/cm³, a 384 mm² section weighs 1.037 kg/m after rounding.
Let YULUX review your drawings before pricing.
Send us your window schedule, floor plans or photos. We review opening sizes, system direction, glass, hardware, finish and packing scope before quoting.