Which joints in a window combination are made in the factory versus on site—and how do I get that written into the quote before signing off?
Use factory joining if the full assembly fits your transport and lifting path. Switch to site joining when smaller units are needed to clear tight access and you have a documented site-coupling detail. To give a sense of the site work required, AMIA's coupled-window instruction recommends bench assembly 1 day before installation and generally 2 people to install the coupled unit.
Choose the delivered assembly
| Site condition | Choose | Cost or construction consequence |
|---|---|---|
| Clear lifting route for the complete combination | Factory-joined assembly | Largest packed piece, with the combination joint completed before dispatch |
| Large elevation with limited truck or crane access | Factory-joined subgroups | Smaller lifts, with specified subgroup joints completed on site |
| Access admits only individual frames | Separate frames with the system's site-joint detail | Allow bench space, joining labour, sealant curing and inspection before concealment |
Pinpoint the joint that changes the installation
Corner joints connect mitred or squared profiles within a single frame. An internal mullion splits one continuous outer frame. A coupling joint links separate, complete frames. On shop drawings, follow the outer head and sill lines to tell an internal mullion apart from a frame-to-frame coupler.
A building post between two windows turns them into separate openings. Each frame then requires its own perimeter fixing and weather seal. Confirm whether that structural post stays or goes before you order a frame-to-frame coupler.
Complete the coupling joint before snapping on covers
AMIA's detail seals frame fasteners and the concealed coupler before engagement, then uses a 15 mm backing rod at the joint. Its heavy-duty detail adds continuous nitrile tape and a fin patch. Apply the detail issued for the selected frame system, including its sealant cure conditions.
Tag the coupler, steel reinforcement, gaskets, fixings, and snap covers to the specific frames they join. Installers must keep the joint accessible until all specified fasteners and continuous wet or dry seals are in place. Photograph these hidden junctions for QA before fitting the trim covers.
Price the handling route
A factory-coupled unit ships as one rigid block. Check its crated width, height, depth, and weight against your truck bed, crane or hoist capacity, site gates, and scaffold bays. Mark the crate dimensions and lifting clearances directly on the site access drawing.
Site coupling adds bench time and assembly labour on the job. Weigh the total installed cost of factory-joined versus split delivery—factoring in container space, craneage, coupling hardware, and dry workspace on site. Any split you approve must keep the specified mullion reinforcement and drainage path intact.
Stage frames close to the opening
Mark a flat unloading zone on the site plan and map the carry path to each opening. Store coupled units in the orientation required by the profile system. Shipping crates are built for transit; once uncrated, frames often need their own A-frames or blocks on site.
If one subgroup arrives before its mating frame, protect the exposed coupling edge and keep the loose coupler kit strapped to that unit. Crate labels need to show both the master opening mark and the individual frame numbers so the crew builds the right elevation.