Window and door handing: lock in the view, hinge side, swing arc, and active panel before ordering
Specify the viewing face, hinge side, swing direction, and active panel for every opening. If a restrictor alters how the sash moves, note the operating sequence. In Roto's ELA/TiltFirst setup, for example, turning the handle to 90° engages the restricted tilt, while 180° unlocks the full turn—provided you unlock it with the key while the sash is closed. Those handle angles apply strictly to that hardware configuration.
Check opening swings against site obstacles
| Constraint | Choose | Trade-off |
|---|---|---|
| Furniture or blinds occupy the room-side sweep | Outward-opening arrangement where exterior space is clear | Leaves interior clearance while projecting beyond the facade |
| An exterior path must remain clear | Inward-opening arrangement where room space is available, or a slider | Moves the clearance requirement indoors or into the sliding track |
| A sliding door must leave one end accessible | Put the active panel at the access end and draw its parking direction | The parked panels occupy the opposite part of the opening |
State which face defines left and right
Mark the viewing face on every elevation sheet sent for fabrication. Andersen's casement standard, for instance, calls out the hinge side viewed from the exterior. Inside-view drawings work fine too, provided they are clearly tagged and converted accurately into your fabricator's shop convention.
When drawing a right-hinged outward casement from the exterior, put the hinge indicator on the right side of the elevation and draw the swing arc on the floor plan. Give any mirrored unit its own mark number and hinge callout.
Identify handed replacement parts
Complete units and spare parts don't always share the same handing rule. Andersen's reference guide, for example, hands operators, locks, and hinges differently from a replacement sash. Always order operating hardware by the manufacturer's exact part code.
If a hardware revision adds a restrictor or changes the opening sequence, update the operation note on the shop drawing. Call out the key-release step and the cleaning position so installers and end users work from the same setup.
Check the complete opening sweep
Plot the full swing arc from the hinge axis, including handle projection. Check clearances against blinds, curtains, kitchen taps, balustrades, downpipes, and adjacent sashes. For tilt-turn units, check both the top-tilt travel and the inward turn sweep.
Show the insect screen on the section detail. You need to reach the window handle easily, and the screen has to slide, roll, or lift out without hitting the sash. Switching to a low-profile handle only buys you the exact millimetre difference of its installed projection.
Mark active and parked panels clearly
On sliding units, tag the fixed panels, the primary sliding sash, its slide arrow, and where it parks. Show the handle and lock positions on the elevation. On bifold doors, indicate the lead pass-door, folding direction, and the clear width taken up by the folded stack.
Stick to one exterior view across the entire elevation sheet. An active sash on the left with an arrow pointing right slides and stacks to the right. Tag the fixed lite behind it so the slide direction stays obvious when the drawing is copied into a purchase order.
Resolve mirrored drawings before fabrication
Cross-check your marked elevations against the room numbers and exterior grid on the floor plan. Watch out for mirrored front-camera phone photos before trusting them for handing. Use a fixed site feature—like a rainwater downpipe or masonry return—to verify left and right.
If you flip an opening's handing, update the hardware part code, screen direction, and drawing revision at the same time. File the superseded drawing with its original order batch so future replacement parts match what was actually built.